Emergency Lighting Systems though not as complex in nature as fire alarm system, they are nevertheless as critical to the safe operation of modern buildings and as such must be subject to a strict regime of maintenance.

Emergency lighting is a self-descriptive term and is lighting for an emergency situation when the main power supply fails. The loss of mains electricity could be the result of a fire or a power cut and the normal lighting supplies fail. This may lead to sudden darkness and a possible danger to the occupants, either through physical danger or panic.

Emergency lighting is normally required to operate fully automatically and give illumination of a sufficiently high level to enable persons of all ages to evacuate the premises safely. Most new buildings now have emergency lighting installed during construction, the design and type of equipment is normally specified by the relevant local authority, architect or consultant.

The British Standard provides the emergency lighting designer with laid down guide lines which form the general basis for the designer to work to. British Standard BS 5266: Part 1: 2005 includes in its scope residential
hotels, clubs, hospitals, nursing homes, schools and colleges, licensed premises, offices, museums, shops, multi-storey dwellings etc. Although this standard recommends the types and durations of emergency lighting systems relating to each category of premise it should be remembered that the standards are minimum safe standards for the types of premises and that a higher standard may be needed for a particular installation.

Type of system
Most emergency lighting schemes fall into one of the following categories:
Non-maintained - The emergency light units only illuminate in the event of a mains failure.
Maintained - The emergency light units are illuminated at all times using the same lamps for both normal and emergency operation.

Sustained - The emergency light units are fitted with two lamps or two sets of lamps. One of which operates on mains 240V AC supply, the other which operates from the battery supply in the event of mains failure. It is basically a non-maintained system with the addition of mains lamps which should be illuminated whenever the premises are occupied.
The type of system and emergency duration is often expressed in abbreviated form as per the following examples:
M3 - Maintained System, emergency duration 3 hours.
NM2 - Non-maintained System, emergency duration 2 hours.
S1 - Sustained System, emergency duration 1 hour.

Emergency Luminaire's
An emergency luminaire will either be of the self-contained type, i.e. with all components integral to the luminaire body (battery, charging circuit, mains ballast etc). Or "slave" to a central battery system where only the lamp (and an inverter if fluorescent) is located within the luminaire body and the supply on power failure is fed from some centralised point.

The majority of systems installed in the United Kingdom are of the self-contained type, but both options have their own advantages and disadvantages.
Emergency Power Supplies
Central Battery Source
Advantages:
Maintenance and routine testing is easier with only one location to consider;
Superior battery life, between 5 and 25 years dependent upon type;
Environmentally stable in a protected environment, luminaire able to operate at relatively high or low ambient temperatures;
Large batteries are cheaper per unit of power and luminaire are usually less expensive.
Disadvantages:
High capital equipment costs;
High installation and wiring costs with essential MICC or Pirelli FP200 type cable to each slave luminaire;
Poor system integrity - failure of battery or wiring circuit can disable a large part of the system;

Requirement for 'battery room' to house cells and charger circuits etc, may also require ventilation of acid gases;
Localised mains failure may not trigger operation of emergency lighting in that area;
Voltage drop on luminaire wired furthest from the central battery could become a problem.

Self-Contained - Single Point
Advantages:
Speedy and low cost installation;
Standard wiring material may be used (failure of mains supply due to cable burning through will automatically satisfy the requirement for a luminaire to be lit);
Low maintenance costs - periodic test and general cleaning only required;
Low hardware equipment costs – no requirement for extended wiring, special ventilation etc.
Greater system integrity with each luminaire independent of the other;
System can easily be extended with additional luminaire's;
No special sub-circuit monitoring requirements.

Disadvantages:
Limited environmental operating range (batteries may be adversely affected by a relatively high ambient temperature);
Battery life is limited to between 2 and 4 years dependant upon application;
Testing requires isolation and observation of luminaire's on an individual basis.
In general then, the decision to use either a central battery or a self-contained system is likely to be cost dominated. If an installation has longevity and low maintenance as priorities, then the higher cost of central battery may be acceptable on a very large project. Usually, luminaire and installation costs will be a major consideration, particularly on smaller jobs, and it is this criterion which makes the self-contained luminaire the most popular choice

ABOUT US


MM Electrical London Ltd was founded by its sole Director in 1992 after serving a seven year Indentured Apprenticeship with what was then the London Electricity Board “ahhh the days”. From its inception, the company’s main objective was to provide London with a premier Emergency Repair and Contract Installation Service.